By David Kaminski-Morrow 2022-07-07T14:02:00+01:00

UK investigators have determined that the windmilling propeller on an experimental Piper M350 – which had been modified with a hydrogen fuel-cell engine – locked out power to the electric motors, leading to a forced landing which badly damaged the aircraft.

The ZeroAvia aircraft (G-HYZA) had been undergoing a flight test during which the crew switched off a high-voltage battery to enable the motors to be supplied solely by power from the hydrogen fuel cell.

But when the battery was switched off, the momentary interruption of power to the motors allowed the propeller to windmill in the airflow, generating a back-voltage which was sufficient to activate an over-voltage protection system.

The aircraft’s experimental powerplant used inverters to convert a 300-400V DC output, from the battery and fuel cell, to an AC input for two electric motors. Each motor had its own inverter and these contained software to provide fault protection – including out-of-tolerance voltage.

For some faults, including over-voltage above a threshold of 820V, the affected inverter would cut power to the motor.

Source: Air Accidents Investigation Branch

Too low to turn back to the airport, the Piper was wrecked as it landed in a field

The aircraft had been conducting a test flight circuit from Cranfield airport, with a pilot and observer, on 29 April last year.

During the downwind leg at 100kt the pilot reduced electrical power, from 95kW to 90kW, to check the effect on airspeed.

The aircraft slowed to 95kt and, as it turned onto the base leg, the observer suggested briefly increasing power to 120kW to regain the lost airspeed, and reducing propeller speed, ahead of a planned battery switch-off which would allow the aircraft to continue only under fuel-cell power.

According to the Air Accidents Investigation Branch, the pilot increased power to 120kW but did not reduce the propeller speed.

As the aircraft approached the runway at about 940ft height, the pilot reduced power to 90kW, set the airspeed to 90kt, then switched off the battery.

“Immediately, all electrical drive to the propeller was lost,” says the inquiry.

It says the momentary interruption of power at battery switch-off allowed the windmilling propeller to turn the motors, effectively causing them to act as generators and creating electrical energy that was fed back to the inverters – sufficient to trigger the over-voltage protection and cause the inverters to lock out the motors.

The inquiry says the loss of power occurred at a point where the aircraft was “not in a position where it could safely glide to the runway”.

As the aircraft started to lose height, the crew made several unsuccessful attempts to reset the system and restore power from the fuel cell and the battery. The aircraft, having travelled the length of Cranfield’s runway 03, was about 320ft above ground when the observer remarked that power could not be regained. After declaring an emergency, the pilot attempted to turn left and position for a landing on runway 21.

“Almost immediately he recognised that he did not have sufficient height to complete the manoeuvre so lowered the landing gear and selected full flap for a forced landing in a field,” says the inquiry.

Investigators state that the aircraft touched down at 87 on level grass but passed through a hedge, breaking off the left wing and coming to a halt with its nose-gear and left-hand main wheel in a ditch.

Neither crew member was injured and the airport fire service arrived quickly. The observer returned to the aircraft, venting the hydrogen tank to the atmosphere and disconnecting the battery to make the aircraft safe.

ZeroAvia has tightened the experimental regime for its hydrogen fuel-cell aircraft testing, including management of commercial pressures, after a UK investigation into a serious loss-of-power accident uncovered safety weaknesses in the programme. The accident, at Cranfield on 29 April last year, involved a modified Piper M350 (G-HYZA) whose single piston ...

India’s Director General of Civil Aviation (DGCA) has queried SpiceJet following a series of recent safety incidents, with the carrier defending its safety standing.

UK accident investigators have disclosed few additional details of the crash involving an experimental hydrogen-electric Piper M350 a year ago, beyond stating that the aircraft suffered a power loss. The aircraft (G-HYZA) had been modified with an electric motor powered by hydrogen fuel cells, and was carrying out test flights ...

Safety concerns over passenger transport of lithium batteries has propelled European regulators to explore whether they could reasonably be detected using airport security screening equipment. Lithium batteries have long been a concern owing to the potential for thermal runaway, and the generation of smoke and fire. “Given their ubiquitous application ...

French investigators have disclosed that an Airbus A320 inbound to Paris narrowly escaped colliding with terrain short of the runway, after an incorrect pressure setting given to the pilots went undetected. Analysis of the serious incident – which took place in poor weather and low visibility – shows the A320 ...

Pilot representatives are urging crews to be particularly cautious when conducting approaches to Hong Kong’s new third runway, owing to potential weather effects and the proximity of terrain. The new runway 25R/07L is located to the north of the airport. Hong Kong’s previous northern runway has been redesignated as a ...

FlightGlobal is the global aviation community’s primary source of news, data, insight, knowledge and expertise. We provide news, data, analytics and advisory services to connect the aviation community globally and help organisations shape their business strategies, identify new opportunities and make better decisions faster.

Site powered by Webvision Cloud